S7/S5 OPC server |
|
|
 |
|
|
Fast And Easy Access to S7 and S5 Controllers
The new version of the S7/S5 OPC Server from Softing is now even more universal in application, higher in performance and easier to use.
With only one server, the S7/S5 OPC Server gives you fast and convenient access to process data in S7-200, S7-300, S7-400 and WinAC controllers, in C7 and M7 units as well as in S5, Pilz or VIPA controllers. The variables are consistently addressed using STEP7 semantics. You can use any OPC complient client application to read and write all input and output data, data blocks, markers, timers and counters in the controllers. Up to 256 controllers can be accessed simultaneously. The PLC program does not need to be modified for communication with the S7/S5 OPC Server.
Access to the controller is available via Ethernet or PROFIBUS, or via serial communication with or without a modem. CPs from various manufacturers, gateways from Softing and NetLink are supported for Ethernet communication. Thanks to the intelligent grouping of read and write requests, the data thoughput is optimized so efficiently that Softing's S7/S5 OPC Servers won the Best In Class award in a practice-related performance comparison of seven S7 OPC servers from renowned manufacturers.
Technical Data:
|
|
|
| Type of communication |
- Access to process data of the S7-300 and S7-400 controllers by PROFIBUS, Ethernet or via serial PC interface (MPI protocol)
- Access to process data of the S7-200 controller by PROFIBUS, Ethernet or via serial PC interface (PPI protocol)
- Access to process data of the Siemens S5 controllers resp. S5 compatible PLCs from INAT and VIPA via Ethernet or serial interface (AS511)
|
| OPC Specification |
Data Access 1.0a, 2.05, 3.0 and OPC XML-DA |
| OPC interfaces |
All mandatory interfaces according to Data Access Specification |
| OPC data types |
VARIANT data types UI1, I1, UI2, I2, UI4, I4, R4, R8, BOOL and arrays with these data types, BSTR |
| S7 data types |
BOOL, BYTE, CHAR, WORD, INT, BCD, S5TIME, DATE, DWORD, DINT, REAL, TIME, TIME of DAY and arrays with these data types, STRING |
| Types of implementation |
OutProc Server, InProc Server, Service |
| Memory areas of the S7 |
E, A, M, Z, DB, PE, PA |
| Hardware requirements |
Windows-enabled PC. For communication by:
PROFIBUS
- Softing PROFIBUS PC cards
- Softing PROFIBUS/Ethernet gateway series (for Windows NT/2000/XP)
- Siemens CP5111, CP5611, CP5613 (Hardware driver from manufacturer required)
Ethernet
- Standard Ethernet card for PC, Siemens CP243-1 for S7-200, CP343-1 for S7-300, CP443-1 for S7-400
- Softing PROFIBUS/Ethernet gateway series, NetLink
Serial MPI resp. PPI
MPI or PPI adapter from Softing or Siemens
|
| Operating systems |
Windows 98/ME/NT4/2000/XP with current service packs |
| Documentation |
Online help in German and English |
|
|
|
Download the free of charge demo version
|
|
|