+31 (0)487 57 27 19

IEC 60870-5

5 artikel(en)

per pagina

  • IEC 60870-5-104 Server to DF1 Master Slave

    5201-104S-DFCM

    The ProLinx family IEC60870-5-104 Server to DF1 Master/Slave communications module (5201-104S-DFCM) creates a powerful connection between devices on an IEC 104 network and DF1 devices. The module is a stand-alone DIN rail-mounted protocol gateway that provides one Ethernet port and up to four serial ports.

    The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.

    The DF1 (DFCM) protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable, providing a great deal of flexibility.

    Meer info
  • IEC 60870-5-104 Server to Modbus Master/Slave

    5201-104S-MCM

    The ProLinx family IEC60870-5-104 Server to Modbus Master/Slave communications module (5201-104S-MCM) creates a powerful connection between devices on a Modbus network and an IEC 104 client device. The module is a stand-alone DIN-rail mounted protocol gateway that provides one Ethernet port and up to four serial ports.

    The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.

    The Modbus (MCM) protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.

    Meer info
  • IEC 60870-5-104 Server to PROFIBUS DP Slave

    5205-104S-PDPS

    The IEC 60870-5-104 Server to PROFIBUS DP Slave Gateway creates a powerful connection between devices on an IEC 104 network and PROFIBUS DP Master devices. This stand-alone DIN-rail mounted gateway provides one PROFIBUS DP-V0 Slave DB9F port and one IEC 104 Server Ethernet port.

    The 104S gateway accepts and responds to commands from a network-connected Client (Master) and can also autonomously generate unsolicited messages for cyclic or event-driven data transmission. Firmware versions 3.00 and later support a wider range of IEC 60870-5-104 Edition 2 data types and Causes of Transmission than previously offered.

    The PROFIBUS Slave protocol supports the PROFIBUS DP-V0 implementation, providing powerful data transfer capability between the ProLinx gateway and a PROFIBUS DP Master. With relatively few options to adjust, the PROFIBUS DP Slave configuration is quick, simple, and easily accomplished using the provided ProSoft Configuration Builder software.

    Meer info
  • IEC 60870-5-101 Slave to PROFIBUS DP Slave Gateway

    5105-101S-PDPS
    The ProLinx IEC60870-5-101 Slave to PROFIBUS DP Slave Gateway creates a powerful connection between devices on an IEC 101 network and a PROFIBUS DP master device. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Slave configurable DB9F port and one IEC 101 Slave configurable serial port. The IEC 60870-5-101 Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. Meer info
  • IEC 60870-5-103 Master to PROFIBUS DP Slave Gateway

    5105-103M-PDPS
    The ProLinx IEC60870-5-103 Master to PROFIBUS DP Slave Gateway creates a powerful connection between devices on an IEC 103 network and PROFIBUS DP master devices. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Slave configurable DB9F port and one IEC 103 Master configurable serial port. The IEC 60870-5-103 Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is userconfigurable, providing a very powerful and flexible host or device interface solution. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. Meer info

5 artikel(en)

per pagina